Off-campus UNL users: To download campus access dissertations, please use the following link to log into our proxy server with your NU ID and password. When you are done browsing please remember to return to this page and log out.

Non-UNL users: Please talk to your librarian about requesting this dissertation through interlibrary loan.

A Portable, Low Power Radiation Detection and Identification System for High Count Rate, Long Term Monitoring

Samuel J Murray, University of Nebraska - Lincoln

Abstract

This dissertation presents the design of a novel radiation detection and identification system that can operate continuously over a period of 8 days while detecting at 30,000 counts per second, consuming a total of 11 mW. The entire system is highly integrated, containing a gamma ray detector, a high voltage detector power supply, and a multichannel analyzer (MCA) system-on-a-chip (SoC), which are all combined into a compact form using a multi-level, configurable printed circuit board design. The MCA SoC, fabricated using a 65 nm CMOS technology, features two enabling resources to allow low power detections at high count rates for detectors that produce slow or fast pulses alike, supporting a variety of detector compounds such as CsI, NaI, and LaBr. The resource designed for slower detectors is based on an array of current mirrors that sample and remove an error current that would otherwise cause significant spectral corruption at higher count rates, while the other is meant for faster detectors and mitigates the error current corruption by stabilizing the signal baseline. Both on-chip circuits are configurable and allow the use of low power, event-driven downstream circuitry and signal processing techniques. Furthermore, the SoC contains a hardware neural network accelerator capable of using the spectral data acquired by the MCA to estimate the constituent radioisotopes within the source, executing in 694 µs and using 1.94 µJ of energy. The SoC also features a 32- bit RISC-V microcontroller that can execute custom programs and transmit the acquired spectral data in less than 10 ms using a serial readout link.

Subject Area

Electrical engineering|Computer science|Energy

Recommended Citation

Murray, Samuel J, "A Portable, Low Power Radiation Detection and Identification System for High Count Rate, Long Term Monitoring" (2023). ETD collection for University of Nebraska-Lincoln. AAI30573463.
https://digitalcommons.unl.edu/dissertations/AAI30573463

Share

COinS