Mechanical & Materials Engineering, Department of
Document Type
Article
Date of this Version
Spring 2-2012
Citation
Huijing He, et al.. "Effects of Mismatched Electrodes on an AT-Cut Quartz Resonator" IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control Vol. 59 Iss. 2 (2012) p. 281 - 286
Abstract
We study thickness-shear and thickness-twist free vibrations of a finite AT-cut quartz resonator with mismatched electrodes. The equations of anisotropic elasticity are used with the omission of the small elastic constant c56. An analytical solution is obtained using Fourier series from which the resonant frequencies, mode shapes, and vibration confinement resulting from the electrode inertia are calculated and examined.
Included in
Mechanics of Materials Commons, Nanoscience and Nanotechnology Commons, Other Engineering Science and Materials Commons, Other Mechanical Engineering Commons
Comments
© 2012 IEEE