"Response of a tall building far from the epicenter of the 11 March 201" by Mehmet Celebi, Izuru Okawa et al.

US Geological Survey

 

Document Type

Article

Date of this Version

2014

Citation

THE STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS. 23, 427–441 (2014)

Comments

This article is a U.S. government work, and is not subject to copyright in the United States.

Abstract

The 11 March 2011M 9.0 Great East Japan earthquake generated significant long-duration shaking that propagated hundreds of kilometers from the epicenter and affected urban areas throughout much of Honshu. Recorded responses of a tall building at 770 km from the epicenter of the mainshock and other related or unrelated events show how structures sensitive to long-period motions can be affected by distant sources. Even when the largest peak input motions to the building is about 3% g, the strong-shaking duration was about 140 s. The 300- to 1000-s prolonged responses of the building are primarily due to a combination of site resonance (e.g. structural fundamental frequency ~0.15 Hz and site frequency ~0.13–0.17 Hz) and low damping (~1–2%) of the structure. Response modification technologies can improve the response of the building during future earthquakes. The need-to-consider risks to such built environments from distant sources are emphasized.

Share

COinS